Airfoil BOEING-VERTOL VR-149 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

BOEING-VERTOL VR-1 airfoil

BOEING-VERTOL VR-1 is 11.0% thick at 35% chord, 1.5% camber at 43% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare BOEING-VERTOL VR-1 with other airfoils

00.250.50.751 = chord
Shape of BOEING-VERTOL VR-1, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness10.97% at 35.3% chord
Max camber1.53% at 43.3% chord
Trailing-edge gap0.00%
Points in source file49
Best L/D (XFOIL, Ncrit 9)114.8 at 8.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

49 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00030.6 at 5°0.95 at 8.75°0.0219
100,00047.0 at 4.25°0.99 at 9.25°0.0145
150,00056.9 at 3.75°1.03 at 9.75°0.0118
200,00063.5 at 3.5°≥ 1.04 at 10° Stall not computed0.0103
500,00072.6 at 3°1.20 at 12.25°0.0064
1 million77.3 at 2.5°1.32 at 15°0.0049
2 million90.9 at 7°1.50 at 17.75°0.0044
5 million114.8 at 8.5°≥ 1.79 at 20° Stall not reached0.0049
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00030.0 at 4.75°0.99 at 10.25°0.0209
100,00044.1 at 3.75°1.05 at 10.75°0.0140
150,00051.7 at 3°1.11 at 11.75°0.0112
200,00053.6 at 3°1.15 at 12.75°0.0095
500,00061.1 at 6°1.27 at 15°0.0064
1 million75.6 at 7°1.41 at 16.75°0.0056
2 million91.1 at 7.75°1.60 at 18.75° No clear stall0.0060
5 million114.3 at 9.5°≥ 1.81 at 20° Stall not reached0.0060
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources