Airfoil SD8000-089-8861 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3Wind tunnel: UIUC LSAT, 3 tests

SD8000-089-88 airfoil

SD8000-089-88 is 8.9% thick at 29% chord, 1.7% camber at 49% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million. Wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests.

Compare SD8000-089-88 with other airfoils

00.250.50.751 = chord
Shape of SD8000-089-88, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness8.86% at 29.4% chord
Max camber1.72% at 48.9% chord
Trailing-edge gap0.00%
Points in source file61
Best L/D (XFOIL, Ncrit 9)125.0 at 6.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

61 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil + wind tunnel

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00033.6 at 5.25°1.06 at 9.25°0.0167
100,00049.3 at 4.5°1.15 at 10.25°0.0128
150,00058.2 at 4°1.20 at 11.25°0.0103
200,00064.1 at 3.75°1.23 at 11.25°0.0086
500,00080.5 at 3.5°1.32 at 12.75°0.0054
1 million92.2 at 4.75°1.45 at 14.5°0.0046
2 million106.0 at 6.25°1.62 at 15.5°0.0046
5 million125.0 at 6.5°1.80 at 17.75°0.0049
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00034.6 at 5°1.10 at 10.5°0.0168
100,00046.7 at 4.5°1.18 at 11.5°0.0120
150,00053.2 at 4.5°1.21 at 12°0.0095
200,00057.9 at 5°1.25 at 12.5°0.0082
500,00074.4 at 5.75°1.38 at 14°0.0063
1 million87.6 at 6.5°1.53 at 15.25°0.0062
2 million101.4 at 6.5°1.66 at 16.5°0.0061
5 million119.6 at 6.5°1.79 at 18°0.0058

Wind-tunnel measurements

Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT). Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign (UIUC Applied Aerodynamics Group). Free to use and share under the GNU General Public License; licence, copyright notice and the LSAT Manifesto. Never charged for.

  • SoarTech 8: M. S. Selig et al., Airfoils at Low Speeds, SoarTech 8, SoarTech Publications, 1989 (data disk).
  • Volume 1: M. S. Selig, J. J. Guglielmo, A. P. Broeren and P. Giguère, Summary of Low-Speed Airfoil Data, Volume 1, SoarTech Publications, 1995.
How the measurements are shown

SD8000-089-88 was tested in the UIUC low-turbulence wind tunnel: 3 tests with 28 runs. In the charts above the measurements are markers, the XFOIL predictions lines. Lift and moment come from the force balance, drag from a wake rake in separate runs at their own angles, so the two kinds of run are shown separately and never combined. Each run is shown at its own measured Reynolds number; nothing is interpolated.

Wind tunnel vs XFOIL table: clean models only, where the measured Reynolds number is within 5% of one XFOIL was computed at. XFOIL: Ncrit 9. “≥” means the value may be higher (the measured lift run or the XFOIL polar ended before lift fell). Highest and lowest of the measured points, as printed in the source; no curve is fitted.

Wind tunnel vs XFOIL

ReMax lift, measured / XFOILMin drag, measured / XFOIL
100,000Volume 1, SD8000; measured Re: lift 101,800; drag 101,1001.107 / 1.154at 11.41° / 10.25°0.0123 / 0.0128measured at CL -0.07
100,000SoarTech 8, SD8000; measured Re: lift 101,595; drag 102,5001.120 / 1.154at 10.62° / 10.25°0.0111 / 0.0128measured at CL 0.05
150,000SoarTech 8, SD8000; measured Re: drag 154,500– / 1.199no lift run at this Re0.0095 / 0.0103measured at CL 0.33
200,000Volume 1, SD8000; measured Re: lift 202,800; drag 201,6001.186 / 1.231at 11.83° / 11.25°0.0088 / 0.0086measured at CL 0.35
200,000SoarTech 8, SD8000; measured Re: drag 200,000– / 1.231no lift run at this Re0.0087 / 0.0086measured at CL 0.25
All 3 tests and all Reynolds numbers
  • SoarTech 8, SD8000, clean: lift curves at Re 60,113, 80,397, 101,595; drag polars at Re 62,500, 102,500, 154,500, 200,000, 302,300; no moment data.
  • SoarTech 8, SD8000, tripped: drag polars at Re 99,900, 101,300, 104,900, 150,500, 152,200, 153,800, 200,800, 202,100, 206,500, 301,300, 306,100, 311,100; no moment data.
  • Volume 1, SD8000, clean: lift curves at Re 61,300, 101,800, 202,800, 304,300; drag polars at Re 60,800, 101,100, 201,600, 302,100; no moment data.

Reliability and data quality

About these predictions
  • Lines are computer predictions, markers are measurements. The polar lines and the performance table are XFOIL predictions (dashed lines: NeuralFoil estimates). XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. The markers are wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests; see Wind-tunnel measurements below.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources