Airfoil SD703461 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

SD7034 airfoil

SD7034 is 10.5% thick at 26% chord, 3.9% camber at 39% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare SD7034 with other airfoils

00.250.50.751 = chord
Shape of SD7034, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness10.51% at 26.1% chord
Max camber3.89% at 39.4% chord
Trailing-edge gap0.00%
Points in source file61
Best L/D (XFOIL, Ncrit 9)166.6 at 4.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

61 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00027.0 at 11°1.41 at 11.5°0.0274
100,00054.3 at 7°1.46 at 14.5°0.0169
150,00068.1 at 6.25°1.44 at 15°0.0120
200,00077.7 at 6°1.43 at 15.25°0.0099
500,000107.3 at 5.25°1.53 at 13.75°0.0063
1 million128.3 at 5°1.64 at 15.75°0.0053
2 million146.5 at 4.75°1.74 at 16.75°0.0048
5 million166.6 at 4.75°1.86 at 18.25° No clear stall0.0048
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00037.4 at 7.25°1.30 at 11.25°0.0211
100,00057.6 at 6.25°1.37 at 12.25°0.0132
150,00068.7 at 6°1.41 at 13.25°0.0106
200,00076.2 at 5.75°1.44 at 13.25°0.0093
500,00099.5 at 5.25°1.55 at 15°0.0070
1 million116.4 at 5°1.64 at 16.25°0.0063
2 million132.2 at 5°1.73 at 17°0.0061
5 million149.8 at 5.25°1.84 at 17.5° No clear stall0.0060
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources