Airfoil SIKORSKY SC1095141 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

SIKORSKY SC1095 airfoil

SIKORSKY SC1095 is 9.5% thick at 27% chord, 0.8% camber at 27% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare SIKORSKY SC1095 with other airfoils

00.250.50.751 = chord
Shape of SIKORSKY SC1095, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness9.50% at 27.0% chord
Max camber0.81% at 27.0% chord
Trailing-edge gap0.35%
Points in source file141
Best L/D (XFOIL, Ncrit 9)122.9 at 7.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

141 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00025.3 at 3.75°≥ 0.95 at 20° Stall not reached0.0169
100,00034.2 at 3.25°1.04 at 9.75°0.0123
150,00039.7 at 5°1.22 at 12°0.0100
200,000 Doubtful45.3 at 11°1.26 at 12.25°0.0087
500,00069.4 at 10°1.34 at 13°0.0057
1 million87.0 at 9.25°1.43 at 13.75°0.0051
2 million103.5 at 8.5°1.56 at 15.25°0.0056
5 million122.9 at 7.5°1.76 at 17.25°0.0057
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00026.6 at 6°1.02 at 10°0.0169
100,00036.4 at 6.5°1.20 at 12°0.0120
150,00043.1 at 7°1.25 at 12.25°0.0099
200,00048.8 at 10°1.27 at 12.5°0.0085
500,00070.2 at 8.75°1.38 at 13.75°0.0072
1 million85.5 at 8.25°1.49 at 14.75°0.0072
2 million99.7 at 7.5°1.62 at 16°0.0068
5 million116.4 at 7°1.78 at 17.75°0.0064
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Doubtful Use with care; see the reasons. Re 200,000, Ncrit 9: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources