Airfoil NACA 64(1)-212 MOD B (n64212mb)51 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

NACA 64(1)-212 MOD B airfoil (n64212mb)

NACA 64(1)-212 MOD B is 12.1% thick at 35% chord, 1.5% camber at 10% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare NACA 64(1)-212 MOD B with other airfoils

00.250.50.751 = chord
Shape of NACA 64(1)-212 MOD B, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness12.05% at 35.1% chord
Max camber1.50% at 9.9% chord
Trailing-edge gap0.00%
Points in source file51
Best L/D (XFOIL, Ncrit 9)138.6 at 8.25°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

51 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00024.3 at 3.75°≥ 0.92 at 20° Stall not reached0.0201
100,00030.6 at 4°1.13 at 10.5°0.0152
150,00036.7 at 12°1.35 at 13.75°0.0125
200,00045.6 at 12°1.38 at 13.5°0.0108
500,00074.4 at 11.25°1.48 at 14.5°0.0071
1 million96.9 at 10°1.59 at 15.5°0.0058
2 million118.6 at 9.5°1.72 at 17.5°0.0054
5 million138.6 at 8.25°1.87 at 19° No clear stall0.0058
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00025.3 at 6.25°1.07 at 10.25°0.0199
100,00035.1 at 7.75°1.28 at 13°0.0142
150,00044.0 at 10.25°1.35 at 13.5°0.0116
200,00051.3 at 10.75°1.38 at 13.75°0.0102
500,00076.4 at 9.75°1.50 at 15.5°0.0075
1 million95.0 at 9.25°1.61 at 16.5°0.0076
2 million110.4 at 8.25°1.72 at 17.25°0.0069
5 million126.7 at 7.25°1.85 at 19° No clear stall0.0060
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources