Airfoil GRUMMAN K-2178 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GRUMMAN K-2 airfoil

GRUMMAN K-2 is 10.3% thick at 41% chord, 2.5% camber at 90% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GRUMMAN K-2 with other airfoils

00.250.50.751 = chord
Shape of GRUMMAN K-2, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness10.28% at 40.8% chord
Max camber2.45% at 89.6% chord
Trailing-edge gap0.10%
Points in source file178
Best L/D (XFOIL, Ncrit 9)100.7 at 7.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

178 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00021.7 at 4.75°≥ 0.91 at 20° Stall not reached0.0223
100,00028.9 at 4°≥ 0.92 at 20° Stall not reached0.0173
150,00026.7 at 6.25°≥ 0.92 at 20° Stall not reached0.0130
200,000 Doubtful29.0 at 6.75°≥ 0.82 at 8.75° Stall not computed0.0113
500,00044.0 at 6.25°1.05 at 9.75°0.0083
1 million60.4 at 6°1.21 at 11°0.0049
2 million76.3 at 6.75°1.44 at 13.5°0.0034
5 million100.7 at 7.5°1.73 at 16°0.0047
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00021.1 at 6.25°≥ 0.90 at 20° Stall not reached0.0205
100,00025.8 at 7°0.88 at 10°0.0151
150,00030.5 at 6.5°0.97 at 10.25°0.0127
200,00035.1 at 7°1.04 at 10.5°0.0113
500,00052.3 at 6.25°1.25 at 12°0.0066
1 million66.7 at 7°1.40 at 13.25°0.0045
2 million82.6 at 7.75°1.62 at 15°0.0055
5 million103.1 at 7.75°1.81 at 17.5°0.0057
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Doubtful Use with care; see the reasons. Re 200,000, Ncrit 9: XFOIL converged at fewer than three quarters of the angles from −5° to 15°.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources