Airfoil GOE 332 (PFALZ 61)33 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GOE 332 (PFALZ 61) airfoil

GOE 332 (PFALZ 61) is 11.8% thick at 30% chord, 6.4% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 332 (PFALZ 61) with other airfoils

00.250.50.751 = chord
Shape of GOE 332 (PFALZ 61), drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness11.79% at 29.9% chord
Max camber6.36% at 39.9% chord
Trailing-edge gap0.30%
Points in source file33
Best L/D (XFOIL, Ncrit 9)187.9 at 4.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

33 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Unreliable10.5 at 4°≥ 0.76 at 6.75° Stall not computed0.0558
100,00051.9 at 8.5°1.69 at 11.5°0.0222
150,00071.5 at 7°1.66 at 11.75°0.0153
200,00083.7 at 6.5°1.66 at 12.25°0.0127
500,000120.9 at 4.75°1.65 at 11°0.0086
1 million147.1 at 4°1.66 at 14.5°0.0070
2 million168.9 at 3.25°1.77 at 16°0.0063
5 million187.9 at 4.75°1.92 at 17.75° No clear stall0.0062
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00029.5 at 5.5°1.33 at 10.5°0.0288
100,00059.6 at 6.25°1.57 at 11.25°0.0166
150,00074.3 at 5.75°1.58 at 12°0.0135
200,00084.3 at 5.5°1.58 at 11.5°0.0120
500,000113.2 at 3.75°1.58 at 11.5°0.0092
1 million131.2 at 3.75°1.67 at 14.75°0.0080
2 million147.7 at 5.25°1.78 at 16.25°0.0076
5 million167.0 at 4.75°1.92 at 17° No clear stall0.0066
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 50,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources