Airfoil GOE 256 (JUNKERS E)33 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GOE 256 (JUNKERS E) airfoil

GOE 256 (JUNKERS E) is 16.0% thick at 30% chord, 4.7% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 256 (JUNKERS E) with other airfoils

00.250.50.751 = chord
Shape of GOE 256 (JUNKERS E), drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness15.99% at 29.6% chord
Max camber4.71% at 39.6% chord
Trailing-edge gap0.25%
Points in source file33
Best L/D (XFOIL, Ncrit 9)162.4 at 7°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

33 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Unreliable6.1 at 4.5°≥ 0.44 at 5.25° Stall not computed0.0502
100,00045.0 at 7°1.52 at 13.5°0.0225
150,00061.0 at 5.25°1.53 at 12.5°0.0159
200,00069.3 at 4°1.50 at 12.5°0.0132
500,00092.0 at 2.25°1.53 at 16.25°0.0081
1 million112.7 at 5.25°1.60 at 15.25°0.0067
2 million133.9 at 7.25°1.62 at 14.25°0.0063
5 million162.4 at 7°1.73 at 18.5° No clear stall0.0059
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00022.5 at 6.75°1.06 at 13°0.0321
100,00048.3 at 6.75°1.38 at 13.25°0.0181
150,00058.1 at 5.75°1.43 at 13.25°0.0143
200,00064.5 at 4.75°1.43 at 12.75°0.0121
500,00086.2 at 4.5°1.49 at 15.5°0.0094
1 million103.5 at 6.75°1.53 at 14.25°0.0082
2 million122.5 at 7°1.59 at 17.5° No clear stall0.0074
5 million147.7 at 5.5°1.72 at 18.5° No clear stall0.0069
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 50,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources