Airfoil FX 74-Cl5-140 MOD (smoothed) (fx74modsm)79 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3Wind tunnel: UIUC LSAT, 1 test
FX 74-Cl5-140 MOD (smoothed) airfoil (fx74modsm)
FX 74-Cl5-140 MOD (smoothed) is 13.1% thick at 27% chord, 9.7% camber at 42% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million. Wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests.
| Max thickness | 13.08% at 27.2% chord |
|---|---|
| Max camber | 9.72% at 41.6% chord |
| Trailing-edge gap | 0.01% |
| Points in source file | 79 |
| Best L/D (XFOIL, Ncrit 9) | 233.6 at 5.25°, Re 5 million |
Download for CAD made in your browser
Original coordinates (.dat, Selig format, unit chord)
79 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.
Polar charts XFOIL 6.99 + NeuralFoil + wind tunnel
Loading charts…
Performance by Reynolds number XFOIL, Ncrit 9
Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.
Suspicious results. Suspicious drag at Re 500,000 (Ncrit 9): The minimum drag is lower than even a perfectly smooth flat plate with fully laminar flow could achieve, so XFOIL's result can't be right. Suspicious L/D at Re 500,000 (Ncrit 9): The best L/D is far higher than any normal airfoil reaches at this Reynolds number. These polars are still shown, marked, so you can judge them yourself, but don't rely on them.
| Reynolds number | Best L/D | Max lift coefficient | Min drag coefficient |
|---|---|---|---|
| 50,000 Unreliable | 0.5 at 0.5° | ≥ 0.05 at 0.5° Stall not computed | 0.1145 |
| 100,000 Unreliable | 41.8 at 1.75° | 1.54 at 4.75° | 0.0312 |
| 150,000 Doubtful | 62.3 at 2.75° | 2.04 at 9.75° | 0.0218 |
| 200,000 | 76.3 at 3.75° | 2.20 at 10.75° | 0.0184 |
| 500,000 Unreliable Suspicious drag Suspicious L/D | 408.8 at 0.25° | 2.18 at 11.75° | 0.0029 |
| 1 million Doubtful | 152.6 at 4.5° | 2.21 at 11° | 0.0102 |
| 2 million | 193.0 at -2.75° | 2.22 at 10.25° | 0.0044 |
| 5 million | 233.6 at 5.25° | 2.20 at 9.25° | 0.0073 |
Same table for Ncrit 5
| Reynolds number | Best L/D | Max lift coefficient | Min drag coefficient |
|---|---|---|---|
| 50,000 | 28.8 at 1.75° | ≥ 1.50 at 20° Stall not reached | 0.0391 |
| 100,000 | 58.2 at 3° | 1.88 at 9° | 0.0231 |
| 150,000 | 73.5 at 3.75° | 2.06 at 11.5° | 0.0191 |
| 200,000 | 84.2 at 3.75° | 2.08 at 11.5° | 0.0170 |
| 500,000 | 119.7 at 4° | 2.13 at 11.25° | 0.0128 |
| 1 million | 149.7 at 4.25° | 2.15 at 10.5° | 0.0107 |
| 2 million | 180.6 at 5.25° | 2.15 at 9.5° | 0.0090 |
| 5 million | 212.9 at 6.25° | 2.13 at 8.75° | 0.0075 |
What the labels in the table mean
Labels in the table (“≥” means the true value may be higher):
- Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 50,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 500,000, Ncrit 9: Suspicious drag, Suspicious L/D.
- Doubtful Use with care; see the reasons. Re 150,000, Ncrit 9: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 1 million, Ncrit 9: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
- Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
- Stall not computed XFOIL stopped converging before stall was reached.
Where stall wasn't found, you can:
- treat max lift as “at least” the value shown;
- check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
- see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).
On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 5).
Wind-tunnel measurements
Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT). Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign (UIUC Applied Aerodynamics Group). Free to use and share under the GNU General Public License; licence, copyright notice and the LSAT Manifesto. Never charged for.
- Volume 1: M. S. Selig, J. J. Guglielmo, A. P. Broeren and P. Giguère, Summary of Low-Speed Airfoil Data, Volume 1, SoarTech Publications, 1995.
How the measurements are shown
FX 74-Cl5-140 MOD (smoothed) was tested in the UIUC low-turbulence wind tunnel: 1 test with 7 runs. In the charts above the measurements are markers, the XFOIL predictions lines. Lift and moment come from the force balance, drag from a wake rake in separate runs at their own angles, so the two kinds of run are shown separately and never combined. Each run is shown at its own measured Reynolds number; nothing is interpolated.
Wind tunnel vs XFOIL table: clean models only, where the measured Reynolds number is within 5% of one XFOIL was computed at. XFOIL: Ncrit 9. “≥” means the value may be higher (the measured lift run or the XFOIL polar ended before lift fell). Highest and lowest of the measured points, as printed in the source; no curve is fitted.
Wind tunnel vs XFOIL
| Re | Max lift, measured / XFOIL | Min drag, measured / XFOIL |
|---|---|---|
| 100,000Volume 1, FX 74-CL5-140 MOD; measured Re: lift 99,300 | 1.936 / 1.542at 18.66° / 4.75° | – / 0.0312no drag run at this Re |
| 150,000Volume 1, FX 74-CL5-140 MOD; measured Re: lift 148,000 | 2.038 / 2.040at 15.68° / 9.75° | – / 0.0218no drag run at this Re |
| 200,000Volume 1, FX 74-CL5-140 MOD; measured Re: lift 201,700; drag 199,400 | 2.062 / 2.201at 13.75° / 10.75° | 0.0211 / 0.0184measured at CL 1.20 |
All 1 tests and all Reynolds numbers
- Volume 1, FX 74-CL5-140 MOD, clean: lift curves at Re 99,300, 124,600, 148,000, 173,400, 201,700, 302,100; drag polars at Re 199,400; no moment data.
Reliability and data quality
- No shape problems found. The coordinate file passed all automatic checks.
About these predictions
- Lines are computer predictions, markers are measurements. The polar lines and the performance table are XFOIL predictions (dashed lines: NeuralFoil estimates). XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. The markers are wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests; see Wind-tunnel measurements below.
- NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.
Sources
- Coordinates: UIUC Airfoil Coordinates Database (file
fx74modsm.dat, original name “FX 74-Cl5-140 MOD (smoothed)”). Cleaned by this site; see About the data. - Polars: XFOIL 6.99 by Mark Drela and Harold Youngren, run by this site. Settings are listed on About the data.
- NeuralFoil estimates: NeuralFoil 0.3.3 by Peter Sharpe (MIT licence), model “xxxlarge”, run by this site at the same Reynolds numbers, Ncrit values and angles as XFOIL. See About the data.
- Computing at your own conditions: XFOIL 6.99 by Mark Drela and Harold Youngren (GNU GPL), compiled for the browser by this site (source code); NeuralFoil by Peter Sharpe (MIT licence; licence). See About the data.
- Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT), Volume 1. Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign. Parsed and reformatted by this site; no value changed. Licence, copyright notice and Manifesto.