Airfoil FX 68-H-12097 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

FX 68-H-120 airfoil

FX 68-H-120 is 11.8% thick at 25% chord, 2.3% camber at 34% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare FX 68-H-120 with other airfoils

00.250.50.751 = chord
Shape of FX 68-H-120, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness11.81% at 25.0% chord
Max camber2.31% at 34.0% chord
Trailing-edge gap0.00%
Points in source file97
Best L/D (XFOIL, Ncrit 9)119.0 at 5.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

97 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Doubtful28.3 at 4°0.96 at 8.25°0.0226
100,00040.2 at 9.5°1.13 at 10.25°0.0142
150,00048.5 at 9°1.11 at 10.75°0.0114
200,00054.3 at 8.25°1.12 at 15.25°0.0099
500,00075.0 at 7°≥ 1.13 at 13.5° Stall not computed0.0062
1 million91.4 at 6.25°1.18 at 11.75°0.0058
2 million107.5 at 6°1.30 at 12.5°0.0057
5 million119.0 at 5.75°1.53 at 15°0.0056
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00029.2 at 6.75°1.08 at 10.25°0.0205
100,00041.0 at 6.5°1.08 at 11°0.0137
150,00048.6 at 7.5°1.09 at 11.25°0.0112
200,00054.3 at 7.25°1.10 at 11.25°0.0095
500,00073.2 at 6.5°1.17 at 11.75°0.0081
1 million88.3 at 6°1.28 at 12.5°0.0075
2 million98.2 at 5.75°1.44 at 15°0.0070
5 million113.4 at 5.5°1.59 at 16.5°0.0064
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Doubtful Use with care; see the reasons. Re 50,000, Ncrit 9: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 200,000, 1 million, 2 million, 5 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources