Airfoil AH 94-145120 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

AH 94-145 airfoil

AH 94-145 is 14.6% thick at 39% chord, 5.5% camber at 45% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare AH 94-145 with other airfoils

00.250.50.751 = chord
Shape of AH 94-145, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness14.57% at 38.9% chord
Max camber5.50% at 44.6% chord
Trailing-edge gap0.20%
Points in source file120
Best L/D (XFOIL, Ncrit 9)246.6 at 3.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

120 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00019.1 at 13.75°1.49 at 15°0.0512
100,000 Unreliable6.1 at -0.5°≥ 0.28 at -0.25° Stall not computed0.0412
150,000 Unreliable20.0 at 0°≥ 0.70 at 2° Stall not computed0.0237
200,00075.7 at 9.5°1.61 at 10.25°0.0180
500,000135.6 at 7.75°1.62 at 9°0.0096
1 million177.4 at 6.5°1.70 at 18° No clear stall0.0068
2 million215.0 at 6°1.80 at 19.25° No clear stall0.0053
5 million246.6 at 3.75°1.91 at 19.5° No clear stall0.0043
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00014.8 at 13.5°1.35 at 18.25°0.0382
100,00032.7 at 5°1.43 at 19.25° No clear stall0.0216
150,00060.2 at 8°1.48 at 10.25°0.0162
200,00081.2 at 8.25°1.52 at 9.25°0.0136
500,000132.4 at 6.5°1.60 at 18.25° No clear stall0.0087
1 million164.5 at 5.25°1.70 at 18.75° No clear stall0.0067
2 million191.8 at 4°1.79 at 19.75° No clear stall0.0055
5 million202.4 at 3.25°≥ 1.90 at 20° Stall not reached0.0051
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 150,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 200,000, 500,000 (Ncrit 9); Re 50,000, 150,000, 200,000 (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources